Optris CTex LT20, Smallest IR pyrometer for hazardous areas, 22:1, temperature range [-50 .. 975°C]
OPTRIS CTex LT20 is one of the smallest infrared sensors worldwide for precise non-contact temperature measurement from up to -50°C to +975°C, for applications in hazardous areas. Optris CTex pyrometer has approvals for zone 1 (PTB 01 ATEX 2053/E II (1/2) GD [EEx ia/ib] IIC/IIB)
The pyrometer OPTRIS CTex LT20 is equipped with one of the world’s smallest infrared sensors with a high optic resolution for precise non-contact temperature measurement. Additionally, it offers a high variability due to selectable analog outputs as well as several digital interfaces in the electronics box.
Features:
- One of the smallest infrared sensors worldwide with 22:1 optical resolution
- Rugged and usable up to 180°C ambient temperature without cooling
- Separate electronics with easy accessible programming keys and LCD backlit display
- Selectable analog output: 0/4-20 mA, 0-5 V, 0-10 V, thermocouple type K or J
- Optional USB, RS485, RS232 interface, relay outputs (2 x optically isolated), CAN-Bus, Profi bus DP, Ethernet
- Explosion proof version (ATEX): approvals for zone 1 (PTB 01 ATEX 2053/E II (1/2) GD [EEx ia/ib] IIC/IIB)
Real-time data, full device parametrization, suitable for IR Thermometers of Optris CS, CSmicro Series and CT Series
- No additional cost
- No limitation in licensing
- Modern software with intuitive user interface
- Complete parametrization of sensors via Software
- Setup of multiple sensors in different windows
- Data recording for detailed analysis and documentation
Optional accessories: see below You might also like
Measurement Specifications
- Temperature range (scalable via software):
-50°C … 975°C (LT22)
-50°C … 600°C (LT15)
-50°C … 600°C (LT02) - Spectral range: 8 to 14 µm
- Optical resolution (90% energy):
22:1
15:1
2:1 - CF-lens (optional):
0.6 mm @ 10 mm (LT22)
0.8 mm @ 10 mm (LT15)
2.5 mm @ 23 mm (LT02) - System accuracy *1) *2) (at ambient temperature 23 ± 5°C): ± 1% or ± 1°C
- Repeatability *1) *2) (at ambient temperature 23 ± 5°C): ± 0.5% or ± 0.5°C
- Temperature resolution (display): 0.1 K
- NETD *2) *3):
0.05 K (LT22/LT15)
0.1 K (LT02) - Response time (95%): 150 ms
- Emissivity / Gain (adjustable via programming keys or software): 0.100 – 1.100
- Transmissivity (adjustable via programming keys or software): 0.100 – 1.100
- Signal processing (parameter adjustable via software): peak hold, valley hold, average, extended hold function with threshold and hysteresis
General Specifications:
- Environmental rating: IP 65 (NEMA-4)
- Ambient temperature:
sensing head: -20°C … 180°C (130°C at LT02)
electronics: -20°C … 85°C *4) - Storage temperature:
sensing head: -40°C … 180°C (130°C at LT02)
electronics: -40°C … 85°C - Relative humidity: 10 – 95%, non condensing
- Shock: IEC 60068-2-27 (25G and 50G)
- Vibration:IEC 60068-2-6 (sinus shaped), IEC 60068-2-64 (broadband noise)
- Weight:
sensing head 40g,
electronics 420 g - Explosion proof version (ATEX): approvals for zone 1 (PTB 01 ATEX 2053/E II (1/2) GD [EEx ia/ib] IIC/IIB)
Electrical Specifications
- Output / analog:
channel 1: 0/4 – 20 mA, 0-5/10 V, thermocouple J, K
channel 2: sensind head temperature (-20°C – 180°C as 0-5 V or 0-10 V), alarm output - Output / alarm: 24 V / 50 mA (open collector)
- Optional: relay: 2 x 60 V DC/42 V ACeff; 0.4 A; optically isolated
- Output / digital (optional): USB, RS232, RS485 (optional), Modbus RTU, Profibus DP, Ethernet
- Output impedances:
mA max. 500 Ω (with 8-36 V DC)
mV min. 100 kΩ load impedance
thermocouple 20 Ω - Inputs: programmable functional input for external emissivity setting /ambient temperature compensation, trigger (reset of hold functions)
- Cable length: 3 m (standard), 8 m, 15 m
- Power supply: 8-36 V DC
- Current draw: max. 100 mA
Versions
Part number: temperature range / spectral range / optics / max. ambient temperature / cable length
OPTCTEXV2LT02: -50-600 °C / 8-14 μm / 2:1 / 130°C / 3 m cable
OPTCTEXV2LT15: -50-600 °C / 8-14 μm / 15:1 / 180°C / 3 m cable
OPTCTEXV2LT20: -50-975 °C / 8-14 μm / 22:1 / 180°C / 3 m cable
OPTCTEXV2LT02H: -40-975 °C / 8-14 μm / 2:1 / 250°C / 3 m cable
OPTCTEXV2LT20H: -40-975 °C / 8-14 μm / 22:1 / 250°C / 3 m cable
Notes:
- *1) Whichever is greater
- *2) At object temperatures > 0°C, Ɛ = 1
- *3) At time constant 200 ms and TObj 25°C
- *4) The LCD displays capacity may be limited at ambient temperatures below 0 °C.
Suggested Applications
One tool, all devices
The Optris Calculator App combines the spot size calculator for IR pyrometers and the optics calculator for Optris IR cameras. It calculates the spot size for each device at any given distance.
- Certificare ATEX
- PTB 01 ATEX 2053/E II (1/2) GD [EEx ia/ib] IIC/IIB
- Temperature range (°C)
- -50 .. 975 °C
- Accuracy
- ±1 % / ±1 °C
- D:S Ratio
- 22:1
- Spectral range (μm)
- 8 .. 14 µm
- Response time
- 150 ms
- Interfaces
- Inputs: programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions)
Optional: USB, RS232, RS485 (optional), CAN-Bus, Profi bus DP, Ethernet
Outputs/analog: 0/4 - 20 mA, 0-5/10 V, thermocouple J, K - Power
- 8 .. 36 Vcc / max. 100mA
- Operating temperature range (°C)
- -20 °C .. 180 °C (sensing head) / -20 °C .. 85 °C (electronics)
- Dimensions (L x l x H)
- 28 mm x Ø12 mm (sensing head)
89 x 70 x 27 mm (electronics)
1. The prices displayed on the site, including special offers, are valid only for the products in stock, within the available limit!
2. Customized products (eg cables cut to the required length) cannot be refunded and cannot be returned!
3. The images of the products presented on the site are for information purposes only and may differ from the real products!
4. Micronix Plus SRL reserves the right to change the prices and specifications of the products without prior notice.