FLIR Si2-PD, Industrial Acoustic Imaging Camera for Partial Discharge Detection
The FLIR Si2-PD acoustic imaging camera helps you reduce maintenance costs for electrical equipment by offering an effective solution for partial discharge (PD) detection and response. This camera detects, locates, classifies, and assesses PD faults from up to 200 m (656 ft) away, identifying PD issues 30 times smaller than previously possible. It provides on-camera and software-based severity assessments, giving you the decision support needed for precise maintenance decisions.
Key Features:
- Detect, locate, classify, and assess partial discharge (PD) faults from up to 200 m (656 ft) away
- Identify PD 30x smaller than ever before
- On-camera and software-based severity assessment of PD issues, and PD type classification provides best-in-class decision support
- One-handed operation with automatic tuning, 8x zoom, a 12 MP digital camera, and IP54 rating
- Made for enterprise scaling through the use of fleet management functionality so that managers can ensure the tools are being used and maintained properly
Get your partial discharge problems program up and running in minutes
The FLIR Si2-PD is an easy-to-use, stand-alone system for detecting partial discharge problems in high-voltage electrical systems. This lightweight, one-handed solution is designed to help engineering professionals identify issues up to 10 times faster than with traditional methods. With 124 microphones, the Si2-PD produces a precise acoustic image that visually displays ultrasonic information, even in loud environments and at long distances. The acoustic image is overlaid in real time on a digital camera picture, which allows the user to accurately pinpoint the source of the sound. Users can then apply the FLIR Severity Assessment analysis to classify the severity of the issue and provide guidance on recommended actions to resolve the problem. The Si2-PD features a plugin that enables users to import acoustic images to FLIR Thermal Studio suite for offline editing, analysis, and advanced acoustic and thermography report creation. Field analysis and reporting can also be done using the FLIR Acoustic Camera Viewer cloud service. Through a regular maintenance routine, the FLIR Si2-PD can help facilities save money on repairs and increase asset reliability.
Available in additional models which include a cordless battery option: the Si2-LD for leak-detection applications, or the Si2 for both electric utility and leak-detection applications, plus mechanical faults detection.
FIND PARTIAL DISCHARGE PROBLEMS FASTER
- Detect partial discharge and corona up to 10 times faster with ultrasonic imaging vs. traditional methods
- Locate problems precisely, even in loud industrial environments, thanks to high-resolution acoustic images and 124 built-in microphones
- Optimize staff time, as minimal training is required to use the Si124-PD
- View visual and sound images simultaneously
- Operate the lightweight camera with one hand for safety and reduced strain
- Easily review images on the display in bright conditions
IMPROVE RELIABILITY
- Minimize equipment failures and downtime that result from partial discharge issues
- Analyze partial discharge pattern and classify problems to improve reliability of electrical systems
- Classify partial discharge type including negative corona, positive and negative corona, floating discharge, and surface or internal discharge
- Evaluate frequency to determine the type and severity of discharge, allowing maintenance to be scheduled
INSPECT EASILY
- Locate, analyze, and classify discharge easily with this convenient, smart tool
- Safely detect problems from distances up to 200 m
- Validate problems in real time
- Upload, store, and backup data; create reports; and conduct deep analysis using FLIR Acoustic Camera Viewer cloud software or FLIR Thermal Studio suite desktop software
- Operate the lightweight camera with one hand for safety and reduced strain
- Easily review images on the display in bright or dark conditions with this adaptable gain camera
Main Applications:
- Monitor transmission & distribution conductors and components at long distances easily and reduce need for emergency repairs
- Inspect substation transformers to detect PD issues early, before they result in a dangerous and costly explosion
- Find PD issues in any piece of high-voltage equipment to reduce public complaints of radio interference and audible noise
- Field of View (HxV)
- 75° diagonal
- Image Frequency (Hz)
- 60 Hz (Camera), 30 Hz (Acoustic image)
- Frequency (Hz)
- 2 KHz to 130 KHz, adjustable range
- Memory
- 128 GB (internal), 8 GB (external)
- Digital Camera Resolution (pixels)
- 12 Mpixel Color
- Display
- Color 5" TouchScreen, 1280 x 720 pixels, Brightness 1000 cd/m²
- Other functions
- Automatic AI-based severity assessment including recommended actions
- Interfaces
- - USB
- Wi-Fi 2.4 GHz and 5 GHz IEEE 802.11.b/g/n/ac wireless LAN - Power
- Battery Li-Ion; Usage: up to 2.5 h (depends on ambient conditions)
- Operating temperature range (°C)
- –10 °C ... +50 °C
- Dimensions (L x l x H)
- 288 × 182 × 159 mm (camera)
- Weight
- 1.45 Kg (Including All Accessories)
- Ultrasonic Emission Measurement
- 124 low-noise MEMS microphones, real-time sound visualization
- Discharge detection
- Automatic detection 50 / 60 Hz
Discharge classification: Positive and negative corona, Floating discharge, Surface or internal discharge - Detection Distance
- 0.3 m ... 200 m
1. The prices displayed on the site, including special offers, are valid only for the products in stock, within the available limit!
2. Customized products (eg cables cut to the required length) cannot be refunded and cannot be returned!
3. The images of the products presented on the site are for information purposes only and may differ from the real products!
4. Micronix Plus SRL reserves the right to change the prices and specifications of the products without prior notice.